News

Author: SUN Xiu-ling; Yan Feng; Huan Jun; Zhang Shulan; Lee

Agency area: People's Liberation Army 251 Hospital Burn Center; Chinese People's Liberation Army 251 Hospital Burn Center

Source: "Journal of Neuropharmacology" 2000 a 121-121 Page of 1

ACTANEUROPHARMACOLOGICA

Abstract: burn patients in the incidence of bedsores up to 1.2%. Not only increase the suffering of patients after bedsores and sepsis may become lesions, even lead to systemic failure and death. For large area burn patients stand characteristics, the institute developed a FS-A floating plate electric medical bed burn for burn patients bedsore prevention, received good results, are as follows:

Keywords: burn patients bedsores

Burn patients, the incidence of bedsores up to 1.2%. Not only increase the suffering of patients after bedsores and sepsis may become lesions, even lead to systemic failure and death. For large area burn patients stand characteristics, the institute developed a Fs-A floating plate electric burns medical socks for burn patients bedsore prevention, received good results, are as follows:

l Structure and Use

Developed by our institute FS-A floating plate electric medical bed burns, its floating bed sheet (board) of the total l0 tablets, according to even odd divided into two groups of five each group. Each sheet lined with long 100cm, wide 4Ocm, 4cm thick sponge pad, the outer layer leather wrap (easy to clean and disinfect). After the medical power, just tap a button, odd, even a floating deck according to pre-set required on floating, to achieve the purpose of treatment.

2 Clinical data

Our department 1994 to 1999 five-year period, there have been varying degrees of burn area of ​​86 patients used the bed, burns a minimum of 26%, the maximum area of ​​98%, no l cases of bedsores, and no l cases cause wounds deepen 86 patients were cured.

3 Results

3.186 cases of burn patients in the use of the process, I believe that there are easy to replace the bed mattress, keep the bed unit dry and clean, to prevent cross-infection and prevent ulcers and so on. To prevent bedsores play a positive role in burn patients and also use length 100cm, width 40cm gauze pad, surrounded on four Shadai sew, stretch to live board. After the flap can be replaced at any time decrease pollution burn pad, while taking advantage of the lifting flaps ask gap hot air therapy, promote wound dry, crusting.

3.2 odd, even alternating floating plate can alternately intermittent compression skin, avoiding the long-term local tissue pressure, promote blood circulation and exchange perfusion and microcirculation, reduces the occurrence of bedsores another from pressures.

Bed linen during the past 3.3 Torr, such as wiping action is often the cause of bedsores, and the use of the lift flap replacement pad burns, wounds and pressure both on the skin to reduce this incentive, again served to protect newborn epithelial effect.

In summary, the electric medical bed floating slab burn burn patient bedsore prevention, played a positive role. Pressure on the part of the patient and the mattress alternately touching, regular replacement, to ensure that the burn wound dry, clean and sanitary; at the same time, effectively ensure the infusion of local microcirculation, reduces peripheral vascular disease, such as embolism and thrombosis complications.